Maximum levels of human exposure to RF fields at frequencies between 3 kHz and 300 GHz, to prevent adverse human health effects in both controlled and uncontrolled environments.
Electric and Magnetic Field Strength (3 kHz–10 MHz)
Frequency (MHz) | Reference Level Basis | Reference Level (ERL), (V/m, RMS) | Reference Period | |
Uncontrolled Environment | Controlled Environment | |||
0.003–10 | NS | 83 | 170 | Instantaneous* |
1.0–10 | SAR | 87 / ƒ 0.5 | 193 / ƒ 0.5 | 6 minutes** |
Frequency (MHz) | Reference Level Basis | Reference Level (HRL), (A/m, RMS) | Reference Period | |
Uncontrolled Environment | Controlled Environment | |||
0.003–10 | NS | 90 | 180 | Instantaneous* |
0.1–10 | SAR | 0.73 / ƒ | 1.6 / ƒ | 6 minutes** |
Electric Field Strength, Magnetic Field Strength and Power Density (10 MHz–300 GHz)
Frequency (MHz) | Electric Field Strength (ERL), (V/m, RMS) | Magnetic Field Strength (HRL), (A/m, RMS) | Power Density (SRL), (W/m2) | Reference Period (minutes) |
10–20 | 27.46 | 0.0728 | 2 | 6 |
20–48 | 58.07 / ƒ 0.25 | 0.1540 / ƒ 0.25 | 8.944 / ƒ 0.5 | 6 |
48–300 | 22.06 | 0.05852 | 1.291 | 6 |
300–6000 | 3.142 ƒ 0.3417 | 0.008335 ƒ 0.3417 | 0.02619 ƒ 0.6834 | 6 |
6000–15000 | 61.4 | 0.163 | 10 | 6 |
15000–150000 | 61.4 | 0.163 | 10 | 616000 / ƒ 1.2 |
150000–300000 | 0.158 ƒ 0.5 | 4.21×10–4 ƒ 0.5 | 6.67×10–5 ƒ | 616000 / ƒ 1.2 |
Frequency (MHz) | Electric Field Strength (ERL), (V/m, RMS) | Magnetic Field Strength (HRL), (A/m, RMS) | Power Density, (SRL), (W/m2) | Reference Period (minutes) |
10–20 | 61.4 | 0.163 | 10 | 6 |
20–48 | 129.8 / ƒ 0.25 | 0.3444 / ƒ 0.25 | 44.72 / ƒ 0.5 | 6 |
48–100 | 49.33 | 0.1309 | 6.455 | 6 |
100–6000 | 15.60 ƒ 0.25 | 0.04138 ƒ 0.25 | 0.6455 ƒ 0.5 | 6 |
6000–15000 | 137 | 0.364 | 50 | 6 |
15000–150000 | 137 | 0.364 | 50 | 616000 / ƒ 1.2 |
150000–300000 | 0.354 ƒ 0.5 | 9.40×10–4 ƒ 0.5 | 3.33×10–4 ƒ | 616000 / ƒ 1.2 |
Source: Consumer and Clinical Radiation Protection Bureau Environmental and Radiation Health Sciences Directorate Healthy Environments and Consumer Safety Branch Health Canada
SAFETY CODE 6 (2015)