Maximum levels of human exposure to RF fields at frequencies between 3 kHz and 300 GHz, to prevent adverse human health effects in both controlled and uncontrolled environments.

Electric and Magnetic Field Strength (3 kHz–10 MHz)

  Frequency (MHz)  Reference Level BasisReference Level (ERL), (V/m, RMS)    Reference Period
Uncontrolled EnvironmentControlled Environment
0.003–10NS83170Instantaneous*
1.0–10SAR87 / ƒ 0.5193 / ƒ 0.56 minutes**
Electric Field Strength Reference Levels

  Frequency (MHz)  Reference Level BasisReference Level (HRL), (A/m, RMS)    Reference Period
Uncontrolled EnvironmentControlled Environment
0.003–10NS90180Instantaneous*
0.1–10SAR0.73 / ƒ1.6 / ƒ6 minutes**
Magnetic Field Strength Reference Levels

Electric Field Strength, Magnetic Field Strength and Power Density (10 MHz–300 GHz)

  Frequency (MHz)Electric Field Strength (ERL), (V/m, RMS)Magnetic Field Strength (HRL), (A/m, RMS)  Power Density (SRL), (W/m2)  Reference Period (minutes)
10–2027.460.072826
20–4858.07 / ƒ 0.250.1540 / ƒ 0.258.944 / ƒ 0.56
48–30022.060.058521.2916
300–60003.142 ƒ 0.34170.008335 ƒ 0.34170.02619 ƒ 0.68346
6000–1500061.40.163106
15000–15000061.40.16310616000 / ƒ 1.2
150000–3000000.158 ƒ 0.54.21×10–4 ƒ 0.56.67×10–5 ƒ616000 / ƒ 1.2
Reference Levels for Electric Field Strength, Magnetic Field Strength and Power Density in Uncontrolled Environments

  Frequency (MHz)Electric Field Strength (ERL), (V/m, RMS)Magnetic Field Strength (HRL), (A/m, RMS)  Power Density, (SRL), (W/m2)  Reference Period (minutes)
10–2061.40.163106
20–48129.8 / ƒ 0.250.3444 / ƒ 0.2544.72 / ƒ 0.56
48–10049.330.13096.4556
100–600015.60 ƒ 0.250.04138 ƒ 0.250.6455 ƒ 0.56
6000–150001370.364506
15000–1500001370.36450616000 / ƒ 1.2
150000–3000000.354 ƒ 0.59.40×10–4 ƒ 0.53.33×10–4 ƒ616000 / ƒ 1.2
Reference Levels for Electric Field Strength, Magnetic Field Strength and Power Density in Controlled Environments

Source: Consumer and Clinical Radiation Protection Bureau Environmental and Radiation Health Sciences Directorate Healthy Environments and Consumer Safety Branch Health Canada

SAFETY CODE 6 (2015)

Leave a Reply